Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
medRxiv ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38559005

RESUMO

Arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms contain valuable clinical information and play a crucial role in cardiovascular health monitoring, medical research, and managing medical conditions. The features extracted from PPG waveforms have various clinical applications ranging from blood pressure monitoring to nociception monitoring, while features from ABP waveforms can be used to calculate cardiac output and predict hypertension or hypotension. In recent years, many machine learning models have been proposed to utilize both PPG and ABP waveform features for these healthcare applications. However, the lack of standardized tools for extracting features from these waveforms could potentially affect their clinical effectiveness. In this paper, we propose an automatic signal processing tool for extracting features from ABP and PPG waveforms. Additionally, we generated a PPG feature library from a large perioperative dataset comprising 17,327 patients using the proposed tool. This PPG feature library can be used to explore the potential of these extracted features to develop machine learning models for non-invasive blood pressure estimation.

2.
Br J Anaesth ; 118(3): 298-310, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28203792

RESUMO

Cardiac output (CO) measurement is crucial for the guidance of therapeutic decisions in critically ill and high-risk surgical patients. Newly developed completely non-invasive CO technologies are commercially available; however, their accuracy and precision have not recently been evaluated in a meta-analysis. We conducted a systematic search using PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science to review published data comparing CO measured by bolus thermodilution with commercially available non-invasive technologies including pulse wave transit time, non-invasive pulse contour analysis, thoracic electrical bioimpedance/bioreactance, and CO2 rebreathing. The non-invasive CO technology was considered acceptable if the pooled estimate of percentage error was <30%, as previously recommended. Using a random-effects model, sd, pooled mean bias, and mean percentage error were calculated. An I2 statistic was also used to evaluate the inter-study heterogeneity. A total of 37 studies (1543 patients) were included. Mean CO of both methods was 4.78 litres min−1. Bias was presented as the reference method minus the tested methods in 15 studies. Only six studies assessed the random error (repeatability) of the tested device. The overall random-effects pooled bias (limits of agreement) and the percentage error were −0,13 [−2.38 , 2.12] litres min−1 and 47%, respectively. Inter-study sensitivity heterogeneity was high (I2=83%, P<0.001). With a wide percentage error, completely non-invasive CO devices are not interchangeable with bolus thermodilution. Additional studies are warranted to demonstrate their role in improving the quality of care.


Assuntos
Débito Cardíaco , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Assistência Perioperatória/instrumentação , Assistência Perioperatória/métodos , Humanos , Reprodutibilidade dos Testes
5.
Br J Anaesth ; 114(6): 886-92, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25690834

RESUMO

BACKGROUND: Goal directed fluid therapy (GDFT) has been shown to improve outcomes in moderate to high-risk surgery. However, most of the present GDFT protocols based on cardiac output optimization use invasive devices and the protocols may require significant practitioner attention and intervention to apply them accurately. The aim of this prospective pilot study was to evaluate the clinical feasibility of GDFT using a closed-loop fluid administration system with a non-invasive cardiac output monitoring device (Nexfin™, BMEYE, Amsterdam, Netherlands). METHODS: Patients scheduled for elective moderate risk surgery under general anaesthesia were enrolled. The primary anaesthesia team managing the case selected GDFT targets using the controller interface and all patients received a baseline 3 ml kg(-1) h(-1) crystalloid infusion. Colloid solutions were delivered by the closed-loop system for intravascular volume expansion using data from the Nexfin™ monitor. Compliance with GDFT management was defined as acceptable when a patient spent more than 85% of the surgery time in a preload independent state (defined as pulse pressure variation <13%) or when average cardiac index during surgery was >2.5 litre min(-1) m(-2). RESULTS: A total of 13 patients were included in the study group. All patients met the established criteria for delivery of GDFT for greater than 85% of case time. The median length of stay in the hospital was 5 [3-6] days. CONCLUSION: In this pilot study, GDFT management using the closed-loop fluid administration system with a non-invasive CO monitoring device was feasible and maintained a high rate of protocol compliance. CLINICAL TRIAL REGISTRATION: NCT02020863.


Assuntos
Débito Cardíaco/fisiologia , Hidratação/métodos , Monitorização Intraoperatória/métodos , Idoso , Anestesia Geral , Perda Sanguínea Cirúrgica , Estudos de Viabilidade , Feminino , Hidratação/instrumentação , Fidelidade a Diretrizes/estatística & dados numéricos , Hemodinâmica/fisiologia , Humanos , Longevidade , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Fisiológica/métodos , Fotopletismografia/instrumentação , Fotopletismografia/métodos , Projetos Piloto , Estudos Prospectivos , Volume Sistólico/fisiologia
6.
Br J Anaesth ; 114(5): 767-76, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25586725

RESUMO

BACKGROUND: Variation in clinical practice in the perioperative environment and intensive care unit is a major challenge facing modern medicine. The objective of the present study was to analyse intraoperative crystalloid administration practices at two academic medical centres in the USA. METHODS: We extracted clinical data from patients undergoing intra-abdominal procedures performed at UC Irvine (UCI) and Vanderbilt University (VU) Medical Centres. Limiting data to uncomplicated elective surgery with minimal blood loss, we quantified variability in fluid administration within individual providers, between providers, and between types of procedures using a corrected coefficient of variation (cCOV). Regression was performed using a general linear model to determine factors most predictive of fluid administration. RESULTS: For provider analysis and model building, 1327 UCI and 4585 VU patients were used. The average corrected crystalloid infusion rate across all providers at both institutions was 7.1 (sd 4.9) ml kg(-1) h(-1), an overall cCOV of 70%. Individual providers ranged from 2.3 (sd 3.7) to 14 (sd 10) ml kg(-1) h(-1). The final regression model strongly favoured personnel as predictors over other patient predictors. CONCLUSIONS: Wide variability in crystalloid administration was observed both within and between individual anaesthesia providers, which might contribute to variability in surgical outcomes.


Assuntos
Abdome/cirurgia , Hidratação/estatística & dados numéricos , Soluções Isotônicas/uso terapêutico , Padrões de Prática Médica/estatística & dados numéricos , Centros Médicos Acadêmicos/estatística & dados numéricos , Adulto , Idoso , Soluções Cristaloides , Feminino , Hidratação/métodos , Humanos , Soluções Isotônicas/administração & dosagem , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos
8.
Ann Fr Anesth Reanim ; 33(3): e35-41, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24378044

RESUMO

OBJECTIVE: Intraoperative haemodynamic optimization based on fluid management and stroke volume optimization (Goal Directed Fluid Therapy [GDFT]) can improve patients' postoperative outcome. We have described a closed-loop fluid management system based on stroke volume variation and stroke volume monitoring. The goal of this system is to apply GDFT protocols automatically. After conducting simulation, engineering, and animal studies the present report describes the first use of this system in the clinical setting. STUDY DESIGN: Prospective pilot study. PATIENTS: Patients undergoing major surgery. METHODS: Twelve patients at two institutions had intraoperative GDFT delivered by closed-loop controller under the direction of an anaesthesiologist. Compliance with GDFT management was defined as acceptable when a patient spent more than 85% of the surgery time in a preload independent state (defined as stroke volume variation<13%), or when average cardiac index during the case was superior or equal to 2.5l/min/m(2). RESULTS: Closed-loop GDFT was completed in 12 patients. Median surgery time was 447 [309-483] min and blood loss was 200 [100-1000] ml. Average cardiac index was 3.2±0.8l/min/m(2) and on average patients spent 91% (76 to 100%) of the surgery time in a preload independent state. Twelve of 12 patients met the criteria for compliance with intraoperative GDFT management. CONCLUSION: Intraoperative GDFT delivered by closed-loop system under anaesthesiologist guidance allowed to obtain targeted objectives in 91% of surgery time. This approach may provide a way to ensure consistent high-quality delivery of fluid administration and compliance with perioperative goal directed therapy.


Assuntos
Hidratação/métodos , Cuidados Intraoperatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Ponte de Artéria Coronária , Feminino , Hidratação/instrumentação , Objetivos , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatectomia , Projetos Piloto , Estudos Prospectivos , Volume Sistólico , Procedimentos Cirúrgicos Operatórios/métodos
10.
Br J Anaesth ; 107(3): 329-35, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21680600

RESUMO

BACKGROUND: Plethysmographic variability index (PVI) is an accurate predictor of fluid responsiveness in mechanically ventilated patients. However, the site of measurement of the plethysmographic waveform impacts its morphology and its respiratory variation. The goal of this study was to investigate the ability of PVI to predict fluid responsiveness at three sites of measurement (the forehead, ear, and finger) in mechanically ventilated patients under general anaesthesia. METHODS: We studied 28 subjects after induction of general anaesthesia. Subjects were monitored with a pulmonary artery catheter and three pulse oximeter sensors (the finger, ear, and forehead). Pulse pressure variation, central venous pressure, cardiac index (CI), and PVI measured at the forehead, ear, and finger (PVI(forehead), PVI(ear), and PVI(finger)) were recorded before and after fluid loading (FL). Subjects were responders to volume expansion if CI increased >15% after FL. RESULTS: Areas under the receiver-operating curves to predict fluid responsiveness were 0.906, 0.880, and 0.836 for PVI(forehead), PVI(ear), and PVI(finger), respectively (P<0.05). PVI(forehead), PVI(ear), and PVI(finger) had a threshold value to predict fluid responsiveness of 15%, 16%, and 12% with sensitivities of 89%, 74%, and 74% and specificities of 78%, 74%, and 67%, respectively. CONCLUSIONS: PVI can predict fluid responsiveness in anaesthetized and ventilated subjects at all three sites of measurement. However, the threshold values for predicting fluid responsiveness differ with the site of measurement. These results support the use of this plethysmographic dynamic index in the cephalic region when the finger is inaccessible or during states of low peripheral perfusion.


Assuntos
Hidratação , Monitorização Intraoperatória/métodos , Pletismografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Curva ROC , Respiração Artificial
11.
Br J Anaesth ; 107(2): 209-17, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21642644

RESUMO

BACKGROUND: How phenylephrine and ephedrine treatments affect global and regional haemodynamics is of major clinical relevance. Cerebral tissue oxygen saturation (Sct(O2) )-guided management may improve postoperative outcome. The physiological variables responsible for Sct(O2) changes induced by phenylephrine and ephedrine bolus treatment in anaesthetized patients need to be defined. METHODS: A randomized two-treatment cross-over trial was conducted: one bolus dose of phenylephrine (100-200 µg) and one bolus dose of ephedrine (5-20 mg) were given to 29 ASA I-III patients anaesthetized with propofol and remifentanil. , mean arterial pressure (MAP), cardiac output (CO), and other physiological variables were recorded before and after treatments. The associations of changes were analysed using linear-mixed models. RESULTS: The CO decreased significantly after phenylephrine treatment [▵CO = -2.1 (1.4) litre min(-1), P<0.001], but was preserved after ephedrine treatment [▵CO = 0.5 (1.4) litre min(-1), P>0.05]. The was significantly decreased after phenylephrine treatment [▵ = -3.2 (3.0)%, P<0.01] but preserved after ephedrine treatment [▵ = 0.04 (1.9)%, P>0.05]. CO was identified to have the most significant association with (P<0.001). After taking CO into consideration, the other physiological variables, including MAP, were not significantly associated with (P>0.05). CONCLUSIONS: Associated with changes in CO, decreased after phenylephrine treatment, but remained unchanged after ephedrine treatment. The significant correlation between CO and implies a cause-effect relationship between global and regional haemodynamics.


Assuntos
Circulação Cerebrovascular/efeitos dos fármacos , Efedrina/farmacologia , Consumo de Oxigênio/efeitos dos fármacos , Fenilefrina/farmacologia , Vasoconstritores/farmacologia , Adulto , Idoso , Anestesia Geral/métodos , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Estudos Cross-Over , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Oximetria/métodos
12.
Ann Fr Anesth Reanim ; 30(5): 403-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21481562

RESUMO

OBJECTIVES: The aims of this study were to test the hypotheses that in the postoperative period following corrective surgery for congenital heart defects: (i) atrio-right ventricular (RA-RV) pacing decreases cardiac output (CO) compared with right atrial (RA) pacing, (ii) atrio-biventricular (RA-BiV) and left ventricular (RA-LV) pacing improves CO compared with RA-RV pacing. STUDY DESIGN: Prospective observational study. PATIENTS: Children 0-2years of age referred for surgery of congenital heart defects were studied during intrinsic rhythm and atrial, atrio-right ventricular, atrio-left ventricular and atrio-biventricular pacing. CO, extrapolated from mean systolic aortic velocity (MSAV), and left ventricular dyssynchrony were assessed using transthoracic echocardiography. RESULTS: RA-RV pacing induced a significant decrease in CO (MSAV 0.52±0.19m/s to 0.46±0.16m/s, p=0.01) and a significant increase in LV dyssynchrony (8.7±7.9ms to 33±21ms, p=0.001). RA-BiV pacing induced a significant increase in CO (MSAV 0.46±0.16m/s to 0.52±0.18m/s, p=0.01) and a significant decrease in LV dyssynchrony (33±21ms to 7±4ms, p=0.0003) compared with RA-RV pacing. RA-LV pacing induced a significant decrease in LV dyssynchrony (33±21ms to 9±7ms, p=0.0007) without a significant improvement of CO compared with RA-RV pacing. CONCLUSIONS: RA-BiV pacing improves CO compared with RA-RV pacing in the early postoperative period following pediatric cardiac surgery. This improvement is related to a reduction in left ventricular dyssynchrony.


Assuntos
Estimulação Cardíaca Artificial/métodos , Procedimentos Cirúrgicos Cardíacos , Hemodinâmica/fisiologia , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Direita , Nó Atrioventricular , Débito Cardíaco/fisiologia , Cardiotônicos/efeitos adversos , Cardiotônicos/uso terapêutico , Ecocardiografia , Eletrocardiografia , Feminino , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Cuidados Pós-Operatórios
13.
Br J Anaesth ; 106(6): 856-64, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21525016

RESUMO

BACKGROUND: Dynamic variables are accurate predictors of fluid responsiveness in adults undergoing mechanical ventilation. They can be determined using respiratory variation in aortic flow peak velocity (▵Vpeak), arterial pulse pressure [▵PP and pulse pressure variation (PPV)], or plethysmographic waveform amplitude [▵POP and pleth variability index (PVI)]. These indices have not been validated in children. We studied the ability of these variables to predict fluid responsiveness in mechanically ventilated children. METHODS: All results are expressed as median [median absolute deviation (MAD)]. Thirty mechanically ventilated children were studied after undergoing general anaesthesia. Mechanical ventilation was maintained with a tidal volume of 10 ml kg(-1) of body weight. ▵PP, PPV, ▵POP, PVI, ▵Vpeak, and aortic velocity-time integral were recorded before and after volume expansion (VE). Patients were considered to be responders to VE when the aortic velocity-time integral increased more than 15% after VE. RESULTS: VE induced significant changes in ▵PP [13 (MAD 4) to 9 (5)%], PPV [15 (5) to 9 (5)%], ▵POP [15 (10) to 10 (6)%], PVI [13 (6) to 8 (5)%], and ▵Vpeak [16 (9) to 8 (3)%] (P<0.05 for all). Differences in ▵PP, ▵POP, PPV, and PVI did not reach statistical significance. Only ▵Vpeak was significantly different between responders (R) and non-responders (NR) to VE [22 (3) vs 7 (1)%, respectively; P<0.001]. The threshold ▵Vpeak value of 10% allowed discrimination between R and NR. CONCLUSIONS: In this study, ▵Vpeak was the most appropriate variable to predict fluid responsiveness.


Assuntos
Anestesia Geral/métodos , Hidratação/métodos , Monitorização Intraoperatória/métodos , Respiração Artificial/métodos , Adolescente , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Criança , Pré-Escolar , Feminino , Hemodinâmica/fisiologia , Humanos , Lactente , Recém-Nascido , Cuidados Intraoperatórios/métodos , Masculino , Pletismografia/métodos , Ultrassonografia
14.
Ann Fr Anesth Reanim ; 29(6): 452-63, 2010 Jun.
Artigo em Francês | MEDLINE | ID: mdl-20547031

RESUMO

OBJECTIVES: To describe preload dependence monitoring tools currently available as well as their limits and potential applications in the anaesthesiology setting. DATA SOURCE: References were obtained from PubMed data bank (http://www.ncbi.nlm.nih.gov/entrez/query.fcgi) using the following keywords: fluid responsiveness, cardiopulmonary interactions, preload dependence, hypovolemia, cardiac output. DATA SYNTHESIS: When measured in optimal conditions, dynamic parameters are the best predictors of fluid responsiveness as compared to static indicators in patients under general anaesthesia and mechanical ventilation. These dynamic parameters rely on cardiopulmonary interactions and allow evaluating preload dependence and the ability of the heart to transform an increase in preload into an increase in cardiac output. Recently, it is possible to monitor these dynamic parameters either invasively (from the arterial pressure waveform) or noninvasively (from the plethysmographic waveform). These tools have intrinsic limitations. However, they have potential to be used for fluid optimization during anaesthesia.


Assuntos
Anestesia , Monitorização Fisiológica , Período Perioperatório , Hemodinâmica , Humanos
15.
Ann Fr Anesth Reanim ; 29(7-8): 512-7, 2010.
Artigo em Francês | MEDLINE | ID: mdl-20541353

RESUMO

BACKGROUND: The aim of the study was to determine the activity and the available human resources working in 66 intensive care unit (ICU). METHODS: One-day audit performed between January 2009 and May 2009 by trained residents. RESULTS: Among 710 beds, 695 (98%) beds were available for 626 patients (occupation rate=90%). The two most frequent causes of admission were shock and pneumonia. On admission, the median SAPS II was 46. More than 75% of patients had at least two organ dysfunctions within their ICU stay (respiratory failure=80%, circulatory failure=67%). At the moment of the audit, the median SOFA score was 3, and 549 (88%) patients had required a billing procedure with an admission SAPS II greater or equal to 15. Twenty seven percent of ICUs had a ratio patients/nurses or patients/aid nurse greater than 2.5 and 4, respectively whereas 58% ICUs had a ratio open beds/nurse greater than 2.5 or open beds/aid nurse greater than 4. CONCLUSION: In this study, more than 75% patients had at least two organ dysfunctions within their ICU stay and 88% required a billing procedure and had an admission SAPS II greater or equal to 15. Nevertheless, the staff resource remained below the 2002 decree in 27% ICUs.


Assuntos
Unidades de Terapia Intensiva , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cuidados Críticos/estatística & dados numéricos , Feminino , França , Hospitais Privados , Hospitais Universitários , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação , Masculino , Auditoria Administrativa , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/epidemiologia , Recursos Humanos de Enfermagem , Admissão e Escalonamento de Pessoal , Pneumonia/epidemiologia , Respiração Artificial , Choque/epidemiologia , Resultado do Tratamento , Recursos Humanos , Adulto Jovem
17.
Ann Fr Anesth Reanim ; 28(6): 537-41, 2009 Jun.
Artigo em Francês | MEDLINE | ID: mdl-19525086

RESUMO

OBJECTIVE: Thoracic bioimpedance has been proposed for cardiac output (CO) determination and monitoring without calibration or thermodilution (ICG Monitor 862146, Philips Medical System, Philips, Suresnes, France). The accuracy and clinical applicability of this technology has not been fully evaluated in the cardiac surgery setting. We designed this prospective study to compare the accuracy of the ICG Monitor (CO(ICG)) versus pulmonary artery catheter standard bolus thermodilution (CO(PAC)) in patients after cardiac surgery or having benefited from cardiac surgery. STUDY DESIGN: Prospective, monocentric. MATERIAL AND METHODS: We studied 13 patients in the postoperative period. CO(ICG) and CO(PAC) were determined at the arrival in the intensive care unit and every four hours. Bland-Altman and Critchley and Critchley's analysis were used to assess the agreement between CO(ICG) and CO(PAC). RESULTS: CO(PAC) ranged from 2.6 to 11.0 l/min and CO(ICG) ranged from 1.8 to 11.7 l/min. There was a significant relationship between CO(PAC) and CO(ICG) (r=0.61 ; p<0.001). Agreement between CO(PAC) and CO(ICG) was -0.5+/-1.3 l/min (Bland-Altman analysis). Percentage error between the two methods was 49% (Critchley and Critchley's analysis). CONCLUSION: We found clinically unacceptable agreement between CO(ICG) and CO(PAC) in this setting. Despite its non invasiveness, this device cannot be recommended for CO monitoring in the postoperative period following cardiac surgery.


Assuntos
Débito Cardíaco/fisiologia , Procedimentos Cirúrgicos Cardíacos , Cardiografia de Impedância/métodos , Monitorização Fisiológica/métodos , Artéria Pulmonar/fisiologia , Idoso , Período de Recuperação da Anestesia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Termodiluição
19.
Ann Fr Anesth Reanim ; 27(10): 808-12, 2008 Oct.
Artigo em Francês | MEDLINE | ID: mdl-18835683

RESUMO

OBJECTIVES: Arterial oxygen saturation (SaO(2)) monitoring using pulse oximeter (SpO(2)) is mandatory in the intensive care unit. The aim was to assess bias and precision of new (SpO(2)ng) and old (SpO(2)og) pulse oximeter technologies in the postoperative period following pediatric cardiac surgery in cyanotic children. STUDY DESIGN: Prospective, monocentric. PATIENTS AND METHODS: Ten patients (7 days to 53 months old) were studied in the postoperative period following palliative cardiac surgery. SaO(2), SpO(2)og, and SpO(2)ng were obtained every 4 hours. SaO(2) of arterial blood sample was obtained from an intra-arterial catheter located in the radial artery, on the same side as the oximeters. Bias and precision were assessed using Bland-Altman analysis. RESULTS: We obtained 136 SaO(2) determinations. Mean SaO(2) was 76+/-15%. SpO(2)og was significantly different from SaO(2), while SpO(2)ng was not different from SaO(2). In 21 (15%) cases, SpO(2)og was not available whereas SpO(2)ng was available in 136 (100%) cases. In the remaining 115 cases, SpO(2)ng's precision was significantly better than SpO(2)og's precision. DISCUSSION: SpO(2)ng is more accurate and more reliable than SpO(2)og for SaO(2) monitoring in the postoperative period following pediatric cardiac surgery in cyanotic children.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas/cirurgia , Monitorização Fisiológica/instrumentação , Oximetria/instrumentação , Oxigênio/sangue , Cuidados Pós-Operatórios/instrumentação , Cateteres de Demora , Pré-Escolar , Cianose/sangue , Feminino , Cardiopatias Congênitas/sangue , Humanos , Lactente , Recém-Nascido , Masculino , Monitorização Fisiológica/métodos , Oximetria/métodos , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Artéria Radial , Reprodutibilidade dos Testes
20.
Br J Anaesth ; 101(2): 200-6, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18522935

RESUMO

BACKGROUND: Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanically ventilated patients under general anaesthesia. METHODS: Twenty-five patients were studied after induction of general anaesthesia. Haemodynamic data [cardiac index (CI), respiratory variations in arterial pulse pressure (DeltaPP), DeltaPOP, and PVI] were recorded before and after volume expansion (500 ml of hetastarch 6%). Fluid responsiveness was defined as an increase in CI > or =15%. RESULTS: Volume expansion induced changes in CI [2.0 (sd 0.9) to 2.5 (1.2) litre min(-1) m(-2); P<0.01], DeltaPOP [15 (7)% to 8 (3)%; P<0.01], and PVI [14 (7)% to 9 (3)%; P<0.01]. DeltaPOP and PVI were higher in responders than in non-responders [19 (9)% vs 9 (4)% and 18 (6)% vs 8 (4)%, respectively; P<0.01 for both]. A PVI >14% before volume expansion discriminated between responders and non-responders with 81% sensitivity and 100% specificity. There was a significant relationship between PVI before volume expansion and change in CI after volume expansion (r=0.67; P<0.01). CONCLUSIONS: PVI, an automatic and continuous monitor of DeltaPOP, can predict fluid responsiveness non-invasively in mechanically ventilated patients during general anaesthesia. This index has potential clinical applications.


Assuntos
Hidratação/métodos , Monitorização Intraoperatória/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Anestesia Geral , Débito Cardíaco , Ponte de Artéria Coronária , Feminino , Hemodinâmica , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Pessoa de Meia-Idade , Oximetria , Pletismografia , Respiração Artificial , Mecânica Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...